POLAGARD FLEX-O-TEX is a high quality water-based, textured, elastomeric wall coating material with waterproofing properties. It may be applied to a wide variety of substrates including concrete, concrete block, stucco, brick, wood and metal. POLAGARD FLEX-O-TEX produces a permanently flexible coating to bridge hairline cracks and withstand thermal movement in a substrate.
OUTSTANDING FEATURES:
§ Provides a textured waterproof surface with extreme durability
§ Produces a breathable coating that remains flexible, tough and waterproof
§ Resists UV, mildew and chemical attack; has excellent alkali and chalking resistance
§
Is safe and convenient to handle, apply and clean up. Has very
low odor
§ Won't trap water or create a vapor barrier
§ Protects the substrate from water damage, moves with thermal changes
§
Available in a wide range of colors
§ Possesses a 15-year life expectancy and an 8-year guarantee
SPECIFICATIONS:
Coating Type: | P.V.C. elastomer |
VOC: | Zero gms/liter |
Pot Life: | Single part |
Shelf Life: | 12 months |
Recommended Thickness: | 10 mils average dry film thickness |
Coverage: | 70 to 100 square feet/gallon |
Packaging: | 5 gallon pails |
Color: | White and other nice colors |
APPLICATION:
Caution! READ THIS ENTIRE DATA SHEET BEFORE CONTINUING. C
Surface must be firm and free of loose debris, dirt, oils, grease, mildew, or any substance that may interfere with bond. All cracks larger than 1/32" need to be filled with a good grade acrylic caulk. All other types of repairs or patches must be made prior to coating as well. Allow repairs to cure before beginning application. Surfaces may be slightly damp but not wet. An overly damp surface may promote runs or sags. It is advisable to test previously coated or treated surfaces by first applying POLAGARD
FLEX-O-TEX to a 4' x 4' area and allow it to cure. Later, inspect the test area for adhesion, voids or sags. It may be necessary to sand or rough previously painted surfaces to improve bond. POLAGARD
FLEX-O-TEX is applied straight out of the can after 2 minutes of low speed stirring or mixing. Apply the product using a brush, texture roller or spray technique. For air operated spray application, use equipment to develop 40 psi with a #260 tip. When spraying, it is advisable to back roll the first coat to eliminate small voids or pocks at the surface. POLAGARD
FLEX-O-TEX may be thinned with no more than 4 oz. of water per gallon if necessary. Apply POLAGARD
FLEX-O-TEX in 2 coats at a wet thickness of about 15-18 mils per coat. Apply the 2nd coat after the first coat has set (about 2-4 hour).
LIMITATIONS:
Do not apply to frozen or saturated surfaces. Do not apply if the temperature is predicted to drop below 35°F within 4 hours of completion of application. Do not apply if precipitation is forecast within 4 hours of completion of application. Shelf life is 12 months in closed containers stored indoors. POLAGARD
FLEX-O-TEX dries faster than ordinary coatings. On warm sunny days, work in the shade as much as possible. Back rolling or retouching areas that have begun to dry may peel the coating.
MAINTENANCE:
If a surface becomes dirty, spray with a mild soapy water solution and rinse with clear water. Do not use high pressure spray or solvents. For harder to clean areas or damaged coating, recoat with Polagard or POLAGARD
FLEX-O-TEX. Clean tools and equipment with water before the product dries; after that, solvent cleaning may be necessary.
PRECAUTIONS:
POLAGARD FLEX-O-TEX is an alkaline based product. Avoid contact with skin and eyes. In case of contact, immediately flush with clear water. For eyes, get medical attention in addition to flushing. Avoid inhalation of spray mist. If spray mist is inhaled, contact a physician immediately. Wear rubber gloves, coveralls and safety goggles when applying this product.
TECHNICAL DATA:
Moisture Vapor Transmission: | 3.36 perms | ASTM E-96 |
Freeze/Thaw (masonry): | 25 cycles | ASTM C-60 |
Elongation: | 50% | ASTM D-412 |
Solids Content: | 74%(B.W.); 66%(B.V.) | ASTM D-1044 |
Weatherometer (5000 hours): | Pass | ASTM G-23 |
Surface Fire Resistance: | Class 1 | ASTM E-108 |
NOTICE: The information presented herein is based on tests and data that Andek Corporation believes to be reliable. It is intended for use by technically qualified personnel at their own discretion and risk. Since conditions of handling and use are beyond our control, we make no warranties, express or implied, and assume no liability in connection with any use of this information. Nothing herein is to be construed as a license to operate or a recommendation to infringe any patent.